SeriesProfileNominal sizesMax. pressureSeal (standard)MaterialValveMulti coupling
HPTEuropean profile Standard6 / 9 / 13 mm10 / 15 / 15 barFKM/Viton (Standard)Brasswith / withoutyes
MPTFrench standard6–38 mm (7 sizes)16 barFKM/Viton (Standard)Brasswith / withoutyes
UPTFrench standard6 / 8 / 12 mm10 barNBR (Standard)Brasswith–
IPTInternational standard (American profile)6 / 9 / 15 mm10 / 15 / 15 barFKM/Viton (Standard)Brasswith / withoutyes
RPTUltra Flow flat face3–50 mm (11 sizes)15–60 barFKM/Viton (Standard)Brass / stainless steelwithyes
CPTflat face Push-Pull3–25 mm (8 sizes)50 barFKM/Viton (Standard)Brass / stainless steelwith–
GPTFull flow25 / 33 / 42 mm10 barNBR (standard)Chrome-plated brasswith–
WHTHigh temperature12 / 19 mm20 barFFKM (Kalrez) as standardBlack-oxidised steelwith–

Hydraulics and industry

SeriesProfileNominal sizesMax. pressureSeal (standard)MaterialValveMulti coupling
PPTISO 7241-1 Series B4–50 mm (9 sizes)50–300 bar (depending on material)NBR (standard)Brasswith / without–
HHTFull flow (International)4–38 mm (8 sizes)75–460 bar (depending on material)NBR (standard)Brass / steel / stainless steelwith–
CPXflat face Push-Pull (Stainless steel)3 / 6 / 9 / 12 / 16 mm180–400 barFKM/Viton (Standard)Fully Stainless steelwith–
HPFISO 16028 Flat-Face6 / 10 / 12 / 16 / 19 / 25 mm250–400 barNBR (Standard)Galvanised steel · stainless steel (VA)with–
SXFHigh Flow Flat-Face6 / 8 / 12 / 16 mm350–450 barFKM/Viton (Standard)Fully Stainless steelwith–
SPFHigh Flow Flat-Face7 / 8 / 11 / 12 mm350–450 barNBR (Standard)Stainless steel / hardened steelwith–

Shut-off or open flow?

Couplings with valve (shut-off) close when disconnected – the medium stays in the circuit and mould changes stay clean. Versions without valve (open, free flow) offer higher flow and less pressure drop; the circuit has to be shut off or drained before disconnecting. Most series offer coupling and nipple in both versions – combinable within the same profile.

Flat-face – when is it worth it?

With flat-face systems (RPT, CPT, CPX, HPF, SXF, SPF) coupling and nipple close with smooth faces. Practically no medium escapes when disconnecting, hardly any air is trapped when connecting, and the faces are easy to clean – ideal for clean rooms, sensitive moulds and frequent reconnection.

Which profile do I have?

The European profile (HPT), French standard (MPT, UPT) and international standard (IPT) differ in the nipple contour. Not sure? Measure the nipple or send us a photo – we identify the profile and name the matching coupling.

Have your profile identified →